Gold plating station: standards that matter
| Item | Standard | Why |
|---|---|---|
| Bath temperature | Per TDS, usually 55-65 C | Colour shifts a full shade when cold |
| Gold concentration | Titrated per shift | Directly controls colour and thickness |
| Current density | Within the supplier window | Too high burns edges, too low gives a dull film |
| Rack contact | Clean, spring loaded | Gold shows contact resistance immediately |
| Thickness check | XRF on flat and edge | Edges run thicker - report min, not average |
FAQ
Why does the same bath give two colours in one day?
Temperature drop and gold concentration drift. Log both every shift before blaming the additive.
How do we keep gold cost under control?
Track grams consumed per 1,000 parts, not the bath price. Drag-out recovery pays back fastest.
Can gold be plated over copper without nickel?
It plates, but diffusion kills the colour within weeks. The nickel barrier is what keeps the tone.