Non-Cyanide Alkaline Copper Process
Bath Control - Intermediate

Non-Cyanide Alkaline Copper Process

Advanced Non-Cyanide Alkaline Copper Process (QLQ System)

Application: Zinc Alloy Zipper Pulls, Belt Buckles, and Hardware.

Standard: REACH Compliant (Zero Cyanide).

1. Technology Overview

Unlike Cyanide Copper, which dissolves zinc chemically (cleaning it), Non-Cyanide Copper is sensitive. It relies on a strong Complexing Agent (Chelator) to hold the copper ions tightly, preventing them from reacting with the zinc substrate (Immersion Copper) which causes peeling.

The QLQ Advantage: We use a "Super-Complexing" technology that creates a bath stable enough to plate directly onto Zinc Alloy with proper activation.


2. Tank Make-up (Bath Formulation)

Note: For a 1000 Liter Tank.

Chemical ComponentConcentrationQuantity for 1000LSourcing
Copper Sulfate Pentahydrate (CuSO₄·5H₂O)35 – 45 g/L35 – 45 kg[Purchase Locally]
Potassium Hydroxide (KOH)50 – 70 g/L50 – 70 kg[Purchase Locally]
[QLQ Product] NC-Base Complexing Agent200 – 250 ml/L200 – 250 Liters[QLQ Product]
[QLQ Product] NC-Make Up Salt30 – 40 g/L30 – 40 kg[QLQ Product]
[QLQ Product] NC-Adjuster (pH Buffer)10 – 15 ml/L10 – 15 Liters[QLQ Product]
[QLQ Product] NC-Brightener1 – 2 ml/L1 – 2 Liters[QLQ Product]
  • Warning: Do NOT use Sodium Hydroxide (NaOH). Potassium (KOH) provides better conductivity and solubility for this specific non-cyanide system.


3. Operational Parameters

ParameterRangeOptimal
pH Value9.2 – 10.09.5
Temperature55°C – 65°C60°C
Cathode Current Density0.5 – 2.0 A/dm²1.0 A/dm²
Anode Current Density0.5 – 1.5 A/dm²1.0 A/dm²
Voltage3 – 6 V4 V
Anode MaterialOFHC Copper (Oxygen-Free High Conductivity)Required
AgitationStrong Mechanical Rocker or Filter FlowNo Air Agitation (Avoids oxidation)
FiltrationContinuous, 5–10 MicronsRequired

4. Step-by-Step Make-up Procedure (SOP)

Crucial: The order of addition determines success. If you add Copper Sulfate before the Complexing Agent, it will precipitate and ruin the bath.

  1. Cleaning: Thoroughly clean the tank (leach with 5% Sulfuric Acid, then rinse).

  2. Water: Fill the tank with Pure Water (RO) to 50% volume.

  3. Complexing Agent: Add the [QLQ Product] NC-Base Complexing Agent and [QLQ Product] NC-Make Up Salt. Stir until fully dissolved.

  4. Heating: Heat the solution to 50°C.

  5. Copper Addition: In a separate bucket, dissolve the Copper Sulfate in hot water.

    • Slowly add the dissolved copper into the main tank while stirring vigorously.

    • Observation: The solution should turn a deep, clear blue. If it turns cloudy, stop and add more Complexing Agent.

  6. pH Adjustment: Dissolve Potassium Hydroxide (KOH) and add slowly to raise the pH to 9.5.

    • Note: The reaction generates heat. Be careful.

  7. Top Up: Fill water to the final volume.

  8. Additives: Add [QLQ Product] NC-Adjuster and NC-Brightener.

  9. Dummy Plating: Electrolyze at low current (0.2 A/dm²) for 4-6 hours to stabilize the chemistry.


5. Critical Precautions for Zinc Alloy (Must Read)

1. The "Live Entry" Rule

  • The Problem: In non-cyanide baths, if a zinc part sits in the solution without electricity, the copper will loosely deposit onto the zinc (Immersion Copper). This layer will peel off later.

  • The Solution: The barrel MUST be rotating and the Rectifier MUST be ON (Preset to 2-3V) before the barrel touches the liquid. The current must hit the parts the instant they enter the water.

2. Activation is Different

  • Do not use strong acid before this bath.

  • Use [QLQ Product] Acid Activation Salt (Fluoride-based) for only 5-10 seconds.

  • Recommendation: A "Pre-dip" in a dilute solution of [QLQ Product] NC-Base Complexing Agent (5%) before entering the plating tank helps prevent blistering.

3. Anode Maintenance

  • Use OFHC Copper (Oxygen-Free). Do not use Phosphorus Copper (used for acid copper).

  • Use High-Density Anode Bags (Double layer). The sludge from non-cyanide copper is very fine and causes roughness easily.


6. Analytical Control & Testing Methods

To be a professional QLQ line, you must analyze the bath twice a week.

A. Copper Content Analysis

  1. Pipette 2 ml of bath sample into a flask.

  2. Add 100ml Pure Water.

  3. Add 10ml Ammonia water (NH₄OH) -> Solution turns dark blue.

  4. Add PAN Indicator.

  5. Titrate with 0.05M EDTA until color changes from Blue to Green.

  6. Calculation: Copper (g/L) = ml EDTA × 3.177.

B. pH Check

  • Use a high-temperature resistant pH probe.

  • If pH < 9.2: Add Potassium Hydroxide.

  • If pH > 10.2: Add [QLQ Product] pH Buffer Acid.

C. Hull Cell Test (Daily)

  • Conditions: 1 Amp, 10 Minutes, 60°C.

  • Check:

    • High Current Density Area (Left): Should be semi-bright, not burnt.

    • Low Current Density Area (Right): Must be fully covered with copper. If the zinc substrate is visible (black/grey) on the right side, you lack [QLQ Product] NC-Make Up Salt (Throwing Power).

Bath Control & AnalysisINTERMEDIATENon-Cyanide Alkaline Copper ProcessOperatorSample from the working zone, not the surface - thenumbers differ.ChemistTitrate every shift. A bath analysed weekly is a bathrunning blind.QCA hull cell at 1-2 A for 5 min shows what titrationcannot.ManagerAdditions cost money, impurities cost more - watch Feand Cu.STEP 1Sample & LogSample 250 mlDaily logBatch reference1STEP 2TitrationZn 8-12 g/LNaOH 80-100M 2 g/L2STEP 3Hull Cell1-2 A, 5 minPanel 100 mmRead coverage3STEP 4Adjust & DoseBrightener 0.1 mL/lCorrective addMix 10 min4STEP 5Verify & RecordRe-testRange checkSPC chart5!Dark or rough plate points to metal contamination - carbon treat early.COMMON MISTAKES vs WHAT WORKSfrom shop-floor auditsxAnalyse the bath once a weekvTitrate every shiftxSample from the tank surfacevSample from the working zonexDose brightener in one big additionvSmall additions, mix 10 minutes8-12 g/LZn80-100 g/LNaOH3-sigma SPCControlCASE FROM THE LINECase: dark plate traced to copper contamination from a dropped anode bar.QLQ Surface Treatment | steps, roles, checkpoints, mistakes and a real case
Bath Control & Analysis - process board with operator, chemist, QC and management notes, mistakes and a case.

FAQ - Non-Cyanide Alkaline Copper Process

Straight answers from the shop floor. Ask us on WhatsApp if your case is different.

What safety and environmental controls are required?
Application: Zinc Alloy Zipper Pulls, Belt Buckles, and Hardware. Standard: REACH Compliant (Zero Cyanide).
What are the working parameters and bath formula?
Note: For a 1000 Liter Tank. Chemical Component Concentration Quantity for 1000L Sourcing Copper Sulfate Pentahydrate (CuSO₄·5H₂O) 35 – 45 g/L 35 – 45 kg [Purchase Locally] Potassium Hydroxide (KOH) 50 – 70 g/L 50 – 70 kg [Purchase Locally] [QLQ Product] NC-Base Complexing Agent 200 – 250 ml/L 200 – 250 Liters [QLQ Product] [QLQ Product] NC-Make Up Salt 30 – 40 g/L 30.
What is the step-by-step procedure?
Crucial: The order of addition determines success. If you add Copper Sulfate before the Complexing Agent, it will precipitate and ruin the bath.
How do I prepare the parts before this step?
1. The "Live Entry" Rule The Problem: In non-cyanide baths, if a zinc part sits in the solution without electricity, the copper will loosely deposit onto the zinc (Immersion Copper).
Previous Post
Daily Plating Cost Analysis
Next Post
(SOP) for Barrel Plating Masters