Alcance de esta guía
Esta guía de nivel intermedio entra en el diagnóstico: leer síntomas, aislar la variable que cambió y corregirla con datos recolectados en la línea.
Dorado y metales preciosos: Las cifras son rangos iniciales estándar de la industria; confírmelas con la TDS de su proveedor antes de fijar ajustes.
Rangos de trabajo y puntos de control
La tabla siguiente es la referencia diaria para Dorado y metales preciosos. Ajuste según la tarjeta y verifique con la columna de control.
| Parameter | Typical range | Control point | Watch out |
|---|---|---|---|
| Bath temperature | 55–65 °C (hard gold) | Thermostat 2× per shift | Cold bath dulls colour |
| Current density | 0.5–1.5 A/dm² | Coulomb counter per rack | High CD gives brittle deposit |
| Gold content | 6–10 g/L as metal | Spectro weekly | Low metal raises resistance |
| Thickness spec | 0.1–0.5 µm decorative; 0.8–1.5 µm wear | XRF per batch | Thin flash wears through |
| Contamination limit | Ni < 20 mg/L, Cu < 10 mg/L | Hull cell check | Drag-in darkens colour |
La capa que importa en tu nivel
Más allá de la tarjeta básica, esta es la capa que importa en su nivel:
| Symptom | Likely variable | Confirm by | First fix |
|---|---|---|---|
| Dull or hazy finish | Bath chemistry drift | Hull cell panel | Rebalance per test |
| Defects cluster on one rack position | Contact or current map | Position thickness map | Repair contact / re-map amps |
| Good-bad-good pattern | Loading or cycle drift | Time-stamped samples | Standardise load weight |
| Defect appears after maintenance | Work just done | Revert one change | Restore and re-verify |
Rutina estándar
Pasos estándar, en orden, para cada turno:
- Pre-plate nickel barrier before gold on zinc alloys
- Rinse thoroughly — soaps poison gold baths
- Weigh racks before and after to estimate deposit
- XRF-check three points per batch
- Return gold-bearing rinse to recovery column

Notas del ingeniero
- Colour drift is usually contamination or low metal, not temperature alone
- Coulomb counting beats time-based dosing for thickness control
- Hard gold for sliding contacts; pure gold for solderability
- Keep a dedicated rinse after nickel to protect the gold bath
- Audit gold salt inventory monthly — losses show up in rinse recovery
Seguridad: Gold baths contain cyanide complexes. Never mix with acid, keep pH above 8.5, and follow cyanide antidote procedures posted at the tank.

Preguntas frecuentes
¿Cómo sé que los ajustes son correctos?
Siga la tabla de rangos y verifique con la columna de control; si el resultado sigue fuera de ventana, pare y avise.
¿Por qué varía el resultado entre turnos?
Siga la tabla de rangos y verifique con la columna de control; si el resultado sigue fuera de ventana, pare y avise.
¿Cuándo debo pedir ayuda a un senior?
Siga la tabla de rangos y verifique con la columna de control; si el resultado sigue fuera de ventana, pare y avise.