Rack Plating Technician - Management

Chrome Burning And Poor Coverage: Cost, metrics and claim defence | Rack Plating Management Guide

Scope of this guide

Management version: this defect as cost and risk — the metrics, audit points and claim defence.

Series: finishing.com recurring questions answered with platingclub line practice. Parameters are industry-standard starting ranges — confirm against your supplier TDS.

Triage: symptom → confirm → first move

SymptomLikely rootConfirm byFirst move
Burnt, gray nodules on edges/high pointsLocal CD far above windowPosition map vs rack layoutCut total amps; add thieves
Bare spots in recesses while edges burnThrowing power ceilingCoverage vs position chartAux anode trial on recess
Burns after bath cools overnightTemperature-CD couplingTemp + amps log overlayInterlock heat to line start
Burns only on new racksContact resistance low, current hoggingContact check by rack ageBalance load across racks
Coverage loss with normal burnCatalyst ratio driftHull cell + titrationCorrect sulfate ratio 100:1

Cost, metrics and defence

Cost lineDriverMetricLever
Strip-and-replate hoursChronic edge burnsFPY by defect familyAmp staging + thieves
EnergyOver-amped coverage chasingkWh per good partGeometry before amps
Rack spendRetired lateRack age vs burn rateRotation schedule
ClaimsBurn escapes polished overAudit failure rateShip gate on first articles

Engineer notes

  • One variable per corrective action; verify with the confirm-by column.
  • Records beat memory: log every trial on the tank card.
  • Two failed actions in a row is a senior call — escalate with your log.
Safety: chromic acid mist is a carcinogen and burns skin. Exhaust running before load-in, face shield, and immediate first aid for any chrome burn.

FAQ

Why does chrome rework cluster in one rack family?
Contact and geometry age together; rack rotation costs less than replate hours.
What proves a geometry fix paid back?
FPY by defect family over four weeks vs the replate hours saved — one chart.
Who owns burn investigations?
The senior on shift with the tank card; audits check the card, not the memory.