Alcance de esta guía
Esta guía de nivel intermedio entra en el diagnóstico: leer síntomas, aislar la variable que cambió y corregirla con datos recolectados en la línea.
Mantenimiento de moldes: Las cifras son rangos iniciales estándar de la industria; confírmelas con la TDS de su proveedor antes de fijar ajustes.
Rangos de trabajo y puntos de control
La tabla siguiente es la referencia diaria para Mantenimiento de moldes. Ajuste según la tarjeta y verifique con la columna de control.
| Parameter | Typical range | Control point | Watch out |
|---|---|---|---|
| Try-out shot count | 20–50 shots per try | Dimensional first-article | Judge on stable shots only |
| Vent depth | 0.01–0.03 mm zinc | Vent impression check | Deep vents flash heavy |
| Polish direction | Along ejection | Ra reading at gates | Cross polish drags filling |
| Cooling flow | Turbulent, per circuit | Flow meter per circuit | Laminar flow warps parts |
| Slide clearance | Per die spec ±0.02 | Blue-check slides | Wear makes mismatch flash |
La capa que importa en tu nivel
Más allá de la tarjeta básica, esta es la capa que importa en su nivel:
| Symptom | Likely variable | Confirm by | First fix |
|---|---|---|---|
| Dull or hazy finish | Bath chemistry drift | Hull cell panel | Rebalance per test |
| Defects cluster on one rack position | Contact or current map | Position thickness map | Repair contact / re-map amps |
| Good-bad-good pattern | Loading or cycle drift | Time-stamped samples | Standardise load weight |
| Defect appears after maintenance | Work just done | Revert one change | Restore and re-verify |
Rutina estándar
Pasos estándar, en orden, para cada turno:
- Clean cores with soft tools — steel scratches vent lands
- Blue-check slides at every service
- Log flow per cooling circuit at each pull
- Photograph vent lands after cleaning
- First-article dimension after every repair

Notas del ingeniero
- Most flash is slide or parting-line wear, not clamp tonnage
- Vent maintenance beats injection-speed tuning for porosity
- Cooling balance decides warp; one clogged circuit hides in averages
- Polish marks copy onto castings — polish along ejection
- Spare cores for the two hottest cavities save the most downtime
Seguridad: Mould handling needs rated slings and clear floors. A dropped insert is a scrapped tool and a foot injury.

Preguntas frecuentes
¿Cómo sé que los ajustes son correctos?
Siga la tabla de rangos y verifique con la columna de control; si el resultado sigue fuera de ventana, pare y avise.
¿Por qué varía el resultado entre turnos?
Siga la tabla de rangos y verifique con la columna de control; si el resultado sigue fuera de ventana, pare y avise.
¿Cuándo debo pedir ayuda a un senior?