Scope of this guide
This intermediate guide goes into diagnosis: reading symptoms, isolating the variable that changed, and fixing it with data you can collect on the line.
Process: Equipment Maintenance. Figures in this guide are industry-standard starting ranges; confirm against your supplier TDS before locking settings.
Working ranges and control points
The table below is the daily reference for a line maintenance. Set by the card, verify by the control point column.
| Item | Check frequency | Healthy reading | Watch out |
|---|---|---|---|
| Rectifier ripple | Monthly scope check | < 5% ripple at load | Ripple dulls deposits |
| Filter pump ΔP | Daily log | Within card band | Rising ΔP starves bath flow |
| Heat exchanger ΔT | Weekly | Within design ΔT | Scale kills cooling slowly |
| Anode bag condition | Weekly visual | No sludge bleed | Burst bags dump sludge |
| Bus bar joints | Quarterly IR scan | Uniform temp | Hot joint drops current |
Diagnose It Fast: the intermediate view
Beyond the basic card, this is the layer that matters at your level:
| Symptom | Likely variable | Confirm by | First fix |
|---|---|---|---|
| Dull or hazy finish | Bath chemistry drift | Hull cell panel | Rebalance per test |
| Defects cluster on one rack position | Contact or current map | Position thickness map | Repair contact / re-map amps |
| Good-bad-good pattern | Loading or cycle drift | Time-stamped samples | Standardise load weight |
| Defect appears after maintenance | Work just done | Revert one change | Restore and re-verify |
Standard routine
- Walk the line with the log book at shift start
- Trend ΔP and ΔT, act on the slope not the point
- IR-scan bus joints under load quarterly
- Record every intervention with part numbers
- Keep critical spares counted, not estimated

Engineer notes
- Rising filter ΔP with steady flow means media loading, not pump failure
- Rectifier ripple shows in the deposit before it shows on gauges
- Scale in exchangers follows water hardness — log conductivity
- Anode bag checks prevent the classic sludge rain on racks
- Spare-parts stock-outs cost more than the parts
Safety: Electrical panels stay live behind doors. Only authorised staff open panels; lock-out before work, verify zero voltage.

FAQ
How often should rectifier ripple be checked?
Monthly under real load, and immediately after any deposit-quality drift.
What does rising filter pressure mean?
Media loading or clogging — service before flow drops starves the bath.
Why IR-scan bus joints?
A hot joint steals current from positions downstream and burns its neighbours.