Scope of this guide
This intermediate guide goes into diagnosis: reading symptoms, isolating the variable that changed, and fixing it with data you can collect on the line.
Process: Pre-treatment & Cleaning. Figures in this guide are industry-standard starting ranges; confirm against your supplier TDS before locking settings.
Working ranges and control points
The table below is the daily reference for a cleaning line. Set by the card, verify by the control point column.
| Stage / parameter | Typical range | Control point | Watch out |
|---|---|---|---|
| Alkaline soak cleaner | 40–60 g/L, 55–70 °C | Titration 2× per shift | Oil layers shorten bath life |
| Soak time | 3–8 min | Visual water-break-free | Under-clean hides under wax |
| Rinse 1 (counter-flow) | TDS < 5000 ppm | Overflow checked hourly | Drag-in salts to next tank |
| Acid activate, 10–20% | 30–60 s | Bright, uniform etch | Over-etch on brass |
| Rinse after acid | Conductivity < 100 µS/cm | Before every plating tank | Chloride carry-over pits nickel |
Diagnose It Fast: the intermediate view
Beyond the basic card, this is the layer that matters at your level:
| Symptom | Likely variable | Confirm by | First fix |
|---|---|---|---|
| Dull or hazy finish | Bath chemistry drift | Hull cell panel | Rebalance per test |
| Defects cluster on one rack position | Contact or current map | Position thickness map | Repair contact / re-map amps |
| Good-bad-good pattern | Loading or cycle drift | Time-stamped samples | Standardise load weight |
| Defect appears after maintenance | Work just done | Revert one change | Restore and re-verify |
Standard routine
- Titrate cleaner bath at shift start
- Rack parts to avoid pockets that trap solution
- Observe water-break test after rinse
- Check acid bath strength before activation
- Record tank temps and concentrations in the log

Engineer notes
- Water-break-free surface is the pass criterion — droplets must sheet, not bead
- Counter-flow rinsing halves water use at the same cleanliness
- Replace cleaner before oil carry-over reaches the soak tank walls
- Acid activation time doubles for aged brass — adjust by visual etch
- Never let parts dry between stages; re-soak instead
Safety: Mixing acids and alkalis in the wrong order can splash hot solution. Add chemicals to water, never water to chemicals, and wear face protection.
FAQ
What is the fastest check that cleaning worked?
The water-break test: rinse and hold the part vertically; film should sheet without beads.
Why do parts flash-rust after rinse?
Rinse water is contaminated or dwell before plating is too long. Increase overflow and shorten transfer.
How often should cleaner baths be titrated?
At least twice per shift, plus after any heavy oil load.