Scope of this guide

This junior-level guide sticks to the basics you must run without help: safe settings, daily checks and the pass criteria you can verify yourself.

Process: Equipment Maintenance. Figures in this guide are industry-standard starting ranges; confirm against your supplier TDS before locking settings.

Working ranges and control points

The table below is the daily reference for a line maintenance. Set by the card, verify by the control point column.

ItemCheck frequencyHealthy readingWatch out
Rectifier rippleMonthly scope check< 5% ripple at loadRipple dulls deposits
Filter pump ΔPDaily logWithin card bandRising ΔP starves bath flow
Heat exchanger ΔTWeeklyWithin design ΔTScale kills cooling slowly
Anode bag conditionWeekly visualNo sludge bleedBurst bags dump sludge
Bus bar jointsQuarterly IR scanUniform tempHot joint drops current

Standard routine

  1. Walk the line with the log book at shift start
  2. Trend ΔP and ΔT, act on the slope not the point
  3. IR-scan bus joints under load quarterly
  4. Record every intervention with part numbers
  5. Keep critical spares counted, not estimated
Equipment Maintenance junior - Live line operation - QLQ workshop photo
Live line operation — QLQ workshop photo

Engineer notes

  • Rising filter ΔP with steady flow means media loading, not pump failure
  • Rectifier ripple shows in the deposit before it shows on gauges
  • Scale in exchangers follows water hardness — log conductivity
  • Anode bag checks prevent the classic sludge rain on racks
  • Spare-parts stock-outs cost more than the parts
Safety: Electrical panels stay live behind doors. Only authorised staff open panels; lock-out before work, verify zero voltage.
Equipment Maintenance junior - Close-up of the working zone - QLQ workshop photo
Close-up of the working zone — QLQ workshop photo

FAQ

How often should rectifier ripple be checked?
Monthly under real load, and immediately after any deposit-quality drift.
What does rising filter pressure mean?
Media loading or clogging — service before flow drops starves the bath.
Why IR-scan bus joints?
A hot joint steals current from positions downstream and burns its neighbours.